Differential Voltage Read-In

Funktion

  • 8 instrumentational amplifiers to read-in 8 voltages.
  • Gain amplifiers and a voltage dividers can be used to amplify or attenuated the signal.
  • Four voltage reference levels can be generated on the PCB and connected to the ref pins.
  • The instr. amp supply as well as two additional variable voltage regulators are on the PCB.
  • BNC or SMA sockets can be used.
  • Fits inside a 19“ 1 HE casing.

Entwickler

Martin Quensen, quensen@iqo.uni-hannover.de

Anwender

  • QAI

Git

Issues