eigenbau:fixedsine [2015/09/03 09:49] – [Table] right align cell kmkeigenbau:fixedsine [2016/06/01 07:48] wfriesen
Line 12: Line 12:
 <table filtervalues> <table filtervalues>
 <caption>Filter values known to work for specific frequencies</caption> <caption>Filter values known to work for specific frequencies</caption>
-^ Freq.          ^ R3    ^ L3      ^ C14     ^ L4      ^ C16     ^ R4    ^ type       ^ +^ Freq.     ^ R3    ^ L3     ^ C14     ^ L4      ^ C16     ^ R4     ^ type       ^ 
-20.00 MHz (?)  | 50 Ω  | 300 nH  270 pF  | 750 nH  120 pF  | 50 Ω  | chebychev  |+16.MHz  | 50 Ω  | 1.5μH  150 pF  | 2.2 μH  100 pF  | 300 Ω  | chebychev  |
 </table> </table>
 ==== Performance ==== ==== Performance ====
Line 25: Line 25:
   * The first prototype was operational in August 2015   * The first prototype was operational in August 2015
 ==== Status ==== ==== Status ====
-Four prototypes were successfully built. They are in use at Mg.                  +About ten devices are in use at Mg.                  
  
 ==== Developer ==== ==== Developer ====
Line 94: Line 94:
   - A polygon on top is not connected to ground.    - A polygon on top is not connected to ground. 
   - Ground should be done more properly   - Ground should be done more properly
 +  - Diode D3 is drawn in the wrong direction in the layout