Line 79: Line 79:
 * gschem bug: rotation of a pin renders an incorrect alignment of the pinnumber attribute. (Alignment changes from lower left to lower right) * gschem bug: rotation of a pin renders an incorrect alignment of the pinnumber attribute. (Alignment changes from lower left to lower right)
 * pcb bug: polygon tool sometimes does not snap to start point.  * pcb bug: polygon tool sometimes does not snap to start point. 
- 
    How to reproduce:    How to reproduce:
-    1set grid to 100 mil +  1set grid to 100 mil 
-    2select polygon tool +  2select polygon tool 
-    3start polygon at (100/100) +  3start polygon at (100/100) 
-    4set polygon corner at (100/300) +  4set polygon corner at (100/300) 
-    5set polygopn corner at (200/300) +  5set polygopn corner at (200/300) 
-    6try to close the triangle with a click at (100/100). pcb will set a corner point at (100/200) instead. +  6try to close the triangle with a click at (100/100). pcb will set a corner point at (100/200) instead. 
  
 #### Oktober2007, PCB v20070912 #### Oktober2007, PCB v20070912
Line 467: Line 466:
 * gschem usability: EE should bring an existing attribute editor to the front of all windows, including non gschem windows. * gschem usability: EE should bring an existing attribute editor to the front of all windows, including non gschem windows.
 * gschem feature request: Add an action to update embeded symbols. This action should try to find embedded symbols in the available library. If there is a diffference, it should display the difference and ask the user whether or not to update the symbol in the schematic. An option should allow to skip the questions and just update all. Crank out a note on what has been done in the log window. * gschem feature request: Add an action to update embeded symbols. This action should try to find embedded symbols in the available library. If there is a diffference, it should display the difference and ask the user whether or not to update the symbol in the schematic. An option should allow to skip the questions and just update all. Crank out a note on what has been done in the log window.
-gschem bug: The multi attribute editor gets insensitive if it is open during switch between schematics. Work-around: Close and open the multi attribute editor.+* gschem bug: The multi attribute editor gets insensitive if it is open during switch between schematics. Work-around: Close and open the multi attribute editor.
 * gschem feature request: "Down Schematics" should assist to maintain inter sheet connections. --> Collect all pin labels of the sub-sheet symbol, compare them to the refdeses of input/output symbols and warn if there is a mismatch. * gschem feature request: "Down Schematics" should assist to maintain inter sheet connections. --> Collect all pin labels of the sub-sheet symbol, compare them to the refdeses of input/output symbols and warn if there is a mismatch.
 * gschem feature request: "Down Schematics" on a sub sheet symbol that does not yet correspond to a schematic shoould open a dedicated sub sheet template. Pin labels of the sub sheet symbol shpuld be collected and turned into input-output symbols * gschem feature request: "Down Schematics" on a sub sheet symbol that does not yet correspond to a schematic shoould open a dedicated sub sheet template. Pin labels of the sub sheet symbol shpuld be collected and turned into input-output symbols